Hello! Welcome to Dongguan Hongbao Electromechanical Technology Co., Ltd. Official website!
The reason of the purity of the nitrogen generator and the solution
The requirements for nitrogen production in medical care are also very strict:
For the high purity of nitrogen, it is generally required to reach 99.9% to 99.99%, that is, the requirement of no oxygen in the national standard; nitrogen production from the nitrogen generator can maintain the constant pressure supply during the production process to ensure the production.
Normal operation; Nitrogen does not contain dust and heat, and can be used for potting injections.
Generally, when the nitrogen production mechanism uses nitrogen, the reasons for the decrease in purity of nitrogen include:
1. The adsorption pressure of the nitrogen generator is unstable, such as being too high, exceeding 0.8Mpa or the adsorption pressure is too low, lower than 0.6Mpa.
2, the air source contains too much oil
3, outlet part of the interface leakage
4, the air intake over the ambassador pressure rose too fast
5, molecular sieve poisoning nitrogen generator
The following measures can be taken to improve the nitrogen purity of the nitrogen generator:
1, reduce the air pressure, increase the intake pressure
2, air intake plus a storage tank
3, remove and re-plug
4, replace the molecular sieve
5, adjust the inlet valve of the nitrogen making machine to reduce the intake air volume, install the water separator before the entrance www.hbqf.cn/admin_master/index.asp
Customers can choose according to their actual conditions, nitrogen generator to achieve their own requirements of nitrogen purity. Our company's high-pressure nitrogen machine is fully computer controlled and the trust of patented products is organized. Customers can