What is the reason for the abnormally low intake air pressure in the compressor? How to rule out?
Time:2014/10/5 14:45:41  Browse:

Due to blockage of air filter, or high resistance of intake line

Excessive spring force will also delay the opening of the inlet.

Method of exclusion:

1. Check the cleaning filter;

2. Change the resistance loss of the intake pipe;

3. Trimming the opening and closing frame to make it flexible;

4. Replace the spring with proper spring force.